CDCP-001 Certified Data Centre Professional (CDCP) Exam

Exam Code: CDCP-001
GAQM provides an international, vendor-neutral credential (CDCP) with a global standard for measuring competency in the core elements of a data center.

The Certified Data Centre Professional (CDCP)™ exam certification indicates a foundational knowledge of critical physical infrastructure in the Data Center. The Certified Data Centre Professional’s have to demonstrate a base level proficiency in the elements of: cooling, fire safety and protection, racks, cabling, management and physical security. The candidate’s who are appearing for the CDCP exam must have sufficient knowledge in data center design and cabling strategies. The CDCP certification can significantly increase productivity and proficiency because certified professionals have the knowledge to successfully overcome obstacles faced in data center design, build and operations.

E-Course Duration: 10 to 15 Hours

e-Competence Framework (e-CF)

The mapping of this certificate against the e-Competence Framework. To know more on e-Competence Framework (e-CF) visit, ECF

The exam comprises of 40 Multiple Choice Questions out of which the candidate needs to score 65% (26 out of 40 correct) to pass the exam.

Exams are online and proctored based, using a webcam and a reliable internet connection exams can be taken anywhere and anytime.

The total duration of the exam is 1 hour (60 Minutes).

No external sources of information may be accessed during the exam held via ProctorU. Further details of the materials permitted are provided:

Identification Proof
If a Candidate does not pass the exam in the second (2nd) attempt, the candidate must wait for a period of at least fourteen (14) calendar days from the date of their attempt to retake the exam for third (3rd) time or any subsequent time.
The exam can be taken any number of times.

The Certified Data Centre Professional (CDCP)™ Certificate is valid for life.
CDCP™ is a trademark of GAQM.

Note: The Certified Data Centre Professional (CDCP)™ Certification requires a mandatory E-Course completion requirement.

Course Outline
Module 1 – Fundamentals of Availability

Introduction
Measuring Business Value
Five 9’s of Availability
Limitations of 99.999%
Factors affecting Availability
A/C Power Conditions
Cooling Issues
Equipment Failures
Natural and Artificial Disasters
Human Errors
Cost of Downtime
Calculating Cost of Downtime

Module 2 – Examining Fire protection methods in the Data Center

Introduction
National Fire Protection Association
Prevention
System Objectives of Data Center Fire Protection System
Fire Triangle
Classes of Fire
Stages of Combustion
Fire Detection Devices
Smoke Detectors
ISTD
Fire Extinguishers
Methods of Fire Supression
Water Sprinkler System
Water Mist Suppression System

Module 3 – Fundamentals of Cabling strategies for Data Centers

Introduction
Cabling
Overview of Cables
Cabling Installation
Cable Layout Architectures
Cable Management
Managing Cables
Cable Maintenance Practices

Module 4 – Fundamentals of Cooling I

Introduction
Evolution
Data Center Cooling
Physics of Cooling
Heat Transfer Methods
Airflow in IT Spaces
Heat Generation
Gas Law
Evaporation
Compression
Condensation
Expansion
Evaporator


Module 5 – Fundamentals of cooling II : Humidilty in the Data Center

Introduction
Cooling Related Devices
Humidity and Static Electricity
Nature of Humidity
Humidity Control in Data Center
Relative Humidity Control
Dew Point Control
Humidification System
Converted Office Space
OSP’s
Short Cycling

Target Audience
System integrators involved in data centre IT operations activities, serving their own data centre or as owned by their customers
Commercial customer who have to maintain their own data centre
Personnel working in commercial companies who are responsible for data centre IT operations
IT, facilities or Data Centre Operations professional

QUESTION 1
Which one of the following is an Objective of Data Center Fire Protection?

A. Information
B. Representation
C. Depression
D. Suppression

Correct Answer: D

QUESTION 2
Which Class of Fires involves energized electrical equipment?

A. Class A
B. Class B
C. Class C
D. Class K

Correct Answer: C

QUESTION 3
Which source is used in fiber cable to transmit data?

A. Signals
B. Electric
C. Light
D. Pulse

Correct Answer: C

QUESTION 4
Which one of the following is an AC Power Quality Anomaly?

A. Signal Distortion
B. Waveform Distortion
C. Backup Condition
D. Attenuation

Correct Answer: B

QUESTION 5
Which Class of Fire involves combustible metals or combustible metal alloys such as magnesium, sodium andpotassium?

A. Class A
B. Class B
C. Class C
D. Class D

Correct Answer: D

Actualkey GAQM CDCP-001 Exam pdf, Certkingdom GAQM CDCP-001 PDF

MCTS Training, MCITP Trainnig

Best GAQM CDCP-001 Certification, GAQM CDCP-001 Training at certkingdom.com

Click to rate this post!
[Total: 0 Average: 0]

About the author /


Archives

Latest

+

Random

+
December 2020
M T W T F S S
 123456
78910111213
14151617181920
21222324252627
28293031